Air Cooled Scroll Water Chiller

Heavy-duty, compact industrial scroll chillers engineered for continuous 24×7 process cooling with a minimum installation footprint. Fourteen models from 2.5 TR to 100 TR, with Danfoss scroll compressors, an oversized Blue Fin condenser coil for high ambient conditions, an electronic expansion valve and VFD control on larger models.

Rated capacity basis
30 °Cwater inlet
10–15 °Cwater outlet
35 °Cambient
Prefer to talk? Call +91 98240 37589

EN series model range

14 models. Scroll sideways to see every column. Figures are approximate — we confirm the final configuration with your quotation.

ModelRefrigerantCooling capacity (kW / TR)Compressor power (kW)Water tank (L)Process pump flow (LPM)Pump pressure (bar)Pump (kW)EvaporatorVFDCircuitsConnected load (kW)Connection size (in / mm)Dimensions L×W×H (in)Weight approx. (kg)
EN 2.5R407C8.7 kW / 2.5 TR2.81407020.55PHE—13.41"43×25×53190
EN 3R407C10.53 kW / 3 TR3.61709020.55PHE—14.41"43×28×54210
EN 5R407C17.55 kW / 5 TR5.227010040.7PHE—16.51" / 2562×34×55290
EN 7.5R407C26.25 kW / 7.5 TR7.930012521PHE—19.51.5" / 4066×36×65355
EN 11R407C38.61 kW / 11 TR11.60Optional24031.8PHE / Shell & tube—114.21.5" / 4074×36×62475
EN 15R407C46.50 kW / 15 TR13.60Optional24031.8PHE / Shell & tube—116.91.5" / 4074×40×62540
EN 20R410A63.18 kW / 20 TR17Optional27021.5Shell & tubeYes120.22" / 5082×45×72850
EN 25R410A80.70 kW / 25 TR20.30Optional40022.2Shell & tubeYes125.12" / 5082×45×72920
EN 30R410A91.50 kW / 30 TR25.80Optional40022.2Shell & tubeYes130.82.5" / 63.588×47×78980
EN 40R410A126 kW / 40 TR34Optional48033.5Shell & tubeYes2412.5" / 63.5117×75×841610
EN 50R410A160 kW / 50 TR40.60Optional65035.5Shell & tubeYes2503" / 75117×75×841750
EN 60R410A193 kW / 60 TR54Optional65035.5Shell & tubeYes262.53" / 75117×75×841900
EN 80R410A260 kW / 80 TR68Optional90037Shell & tubeYes2824" / 100206×75×842300
EN 100R410A351 kW / 100 TR82Optional100037.5Shell & tubeYes21004" / 100206×75×843200

Technical specifications

SeriesEN
Cooling capacity2.5 – 100 TR (8.7 – 351 kW)
Models14
CompressorDanfoss scroll
RefrigerantR407C (2.5 – 15 TR) · R410A (20 – 100 TR)
CondenserAir cooled, Blue Fin coated coil
EvaporatorPHE (up to 7.5 TR) · PHE or shell & tube (11 – 15 TR) · shell & tube (20 TR and above)
Expansion valveElectronic expansion valve (EEV)
VFDStandard from 20 TR
Process pumpSHIMGE, SS-304 wetted parts
Water tank140 – 300 L up to 7.5 TR · optional on larger models
Refrigeration circuits1 (up to 30 TR) · 2 (40 TR and above)
Power supply415 V, 50 Hz

Features & benefits

  • Built for 24×7 dutyHeavy-duty compact industrial design engineered for continuous 24×7 process cooling with a minimum installation footprint.
  • High COPHigh Coefficient of Performance delivering superior cooling efficiency with optimised energy use.
  • Oversized Blue Fin condenserBlue Fin coated aluminium fins designed for high ambient temperatures — better heat rejection, corrosion resistance and stable performance.
  • VFD technologyVariable Frequency Drive for intelligent capacity control, energy savings, reduced starting current and protection against voltage fluctuations and spikes.
  • Danfoss scroll compressorLow vibration, low noise, high volumetric efficiency and long compressor life under critical industrial conditions.
  • Internally grooved copper tubesMaximum refrigerant turbulence, better thermal conductivity and a higher heat-transfer rate.
  • SHIMGE process pumpIndustrial-grade pump with SS-304 wetted components and a multi-stage impeller for high discharge pressure and continuous duty.
  • Electronic expansion valvePrecise refrigerant flow and superheat control, with protection against liquid floodback to the compressor.
  • Low power consumptionOptimised refrigeration circuit for lower operating cost and higher energy efficiency.
  • Microprocessor controlsIntelligent monitoring, safety interlocks and fault diagnostics for reliable, safe operation.
  • Fast pull-downHigh-efficiency refrigeration circuit for faster pull-down and consistent process temperature.
  • Industrial safety protectionsHigh/low pressure cut-off, overload, phase failure, voltage imbalance and anti-freezing protection.
  • Long life, low maintenancePrecision-engineered refrigeration components for long operational life and maximum uptime.
  • Made for harsh environmentsStable performance under continuous high-load conditions.
Technical brochureAvailable on request
Request

Get a quote for the Air Cooled Scroll Water Chiller

Share your application and cooling requirement. Our team will confirm the right configuration and send pricing.

We reply to enquiries by phone or email.